{"product_id":"oem-goodman-pressure-switch-for-acvm961005dxaa-furnace-0130f00070","title":"OEM Goodman Pressure Switch for ACVM961005DXAA Furnace — 0130F00070","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00070 Pressure Switch\u003c\/strong\u003e is a genuine OEM venting safety control for the \u003cstrong\u003eACVM961005DXAA\u003c\/strong\u003e modulating gas furnace and compatible Goodman and Amana models. The pressure switch monitors the negative pressure created by the draft inducer motor and only closes — allowing the ignition sequence to proceed — when proper venting airflow is confirmed. A blocked flue, failing inducer, or cracked hose will keep the switch open, preventing unsafe combustion. A worn or out-of-calibration switch is a leading cause of no-heat and inducer lockout faults.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGenuine Goodman\/Amana OEM part number 0130F00070\u003c\/li\u003e\n\u003cli\u003eDesigned for ACVM961005DXAA and compatible 96% AFUE furnaces\u003c\/li\u003e\n\u003cli\u003eFactory-calibrated negative-pressure trip point (in. w.c.)\u003c\/li\u003e\n\u003cli\u003eSingle-stage diaphragm switch with hose port and spade terminals\u003c\/li\u003e\n\u003cli\u003eDirect-fit replacement with matching bracket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003ePressure-switch setpoints must match the furnace's inducer and venting design exactly. OEM 0130F00070 is calibrated to the correct trip pressure for this model. Generic switches with an incorrect setpoint can either block normal operation or, worse, allow ignition with inadequate venting — a safety risk. OEM is the right choice for combustion-safety parts.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2\/5).\u003c\/strong\u003e Power off, photograph wiring and hose routing, remove the mounting screws, transfer the tubing and leads, and mount the new switch. About 15–20 minutes. Confirm the hose is clear and seated.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Direct Replacement","offer_id":63032477221235,"sku":"0130F00070-GEN","price":13.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048294564211,"sku":"0130F00070","price":18.13,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-pressure-switch-single-0130F00070_0781f1d4-3502-4941-bdf8-424172545449.jpg?v=1782950037","url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-pressure-switch-for-acvm961005dxaa-furnace-0130f00070","provider":"National HVAC Parts","version":"1.0","type":"link"}