{"product_id":"oem-goodman-pressure-switch-for-acvm960805dxaa-furnace-0130f00070","title":"OEM Goodman Pressure Switch for ACVM960805DXAA Furnace — 0130F00070","description":"\u003cp\u003eThe genuine Goodman 0130F00070 pressure switch is the OEM-direct replacement for ACVM960805DXAA 96% AFUE furnaces and matching Goodman\/Amana models. This safety switch monitors the negative draft created by the inducer motor and closes only when proper venting is confirmed. If the inducer draft is weak—or the switch itself fails—the control board halts ignition, producing a furnace that runs the inducer but never lights, often flashing a pressure-switch fault code.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 0130F00070 (OEM Goodman)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Single-stage diaphragm draft\/vacuum pressure switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Proves inducer draft before ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible model:\u003c\/strong\u003e ACVM960805DXAA and related Goodman\/Amana furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Hose port plus spade terminals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003ePressure switches are calibrated to a specific set-point (inches of water column) tuned to this furnace's venting design. The genuine Goodman switch carries the correct trip pressure and port size, so it proves draft accurately. Generic switches with the wrong set-point cause false lockouts or, worse, allow ignition with poor venting. OEM is strongly recommended.\u003c\/p\u003e\u003ch3\u003eInstall difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — disconnect power, pull the hose and wires, unscrew the switch, and reverse. Verify the hose is clear of condensate. Roughly 15 minutes.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Direct Replacement","offer_id":63032476402035,"sku":"0130F00070-GEN","price":13.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048294531443,"sku":"0130F00070","price":18.13,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-0130F00070_1412fa56-6945-4d0f-a6d2-526aae4a424c.jpg?v=1782950035","url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-pressure-switch-for-acvm960805dxaa-furnace-0130f00070","provider":"National HVAC Parts","version":"1.0","type":"link"}