{"product_id":"oem-goodman-pressure-switch-for-acvc960804cnaa-furnace-0130f00436-1","title":"OEM Goodman Pressure Switch for ACVC960804CNAA Furnace — 0130F00436","description":"\u003cp\u003eThe genuine Goodman \u003cstrong\u003e0130F00436 Pressure Switch\u003c\/strong\u003e is the combustion-air \/ draft-proving safety control for the Goodman \u003cstrong\u003eACVC960804CNAA\u003c\/strong\u003e 96% AFUE two-stage variable-speed gas furnace. Connected to the induced-draft blower by a hose, it confirms adequate negative pressure (proper venting and a clear flue\/condensate path) before the control board allows the igniter and gas valve to energize. A failed switch, a clogged hose, or a blocked vent is the usual cause of a furnace that runs the inducer but never lights, often flashing a pressure-switch \/ Code 31 fault.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Air-proving \/ draft pressure switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Venting \u0026amp; inducer draft confirmation before ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0130F00436\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Type:\u003c\/strong\u003e Gas furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e ACVC960804CNAA and related ACVC96 series\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003ePressure switches are calibrated to a specific trip point (in inches of water column) matched to this furnace's inducer and vent design. The OEM \u003cstrong\u003e0130F00436\u003c\/strong\u003e ships with the correct setpoint and port configuration. A generic switch with the wrong rating can nuisance-lockout or fail to detect a true venting blockage, so the genuine Goodman part is strongly recommended.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (3\/5).\u003c\/strong\u003e Disconnect the wiring and pressure hose, remove two mounting screws, and transfer the hose to the new switch without kinks. \u003cstrong\u003eShut off gas and electrical power first.\u003c\/strong\u003e Typical install time: 15–20 minutes. Always inspect the hose and inducer port for condensate or debris before replacing the switch.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057489232243,"sku":"GOODMAN-2894","price":47.94,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-pressure-switch-for-acvc960804cnaa-furnace-0130f00436-1","provider":"National HVAC Parts","version":"1.0","type":"link"}