{"product_id":"oem-goodman-pressure-switch-for-acvc950915dxac-furnace-0130f00100","title":"OEM Goodman Pressure Switch for ACVC950915DXAC Furnace — 0130F00100","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00100 Pressure Switch\u003c\/strong\u003e is a genuine OEM draft-proving control for the Goodman \u003cstrong\u003eACVC950915DXAC\u003c\/strong\u003e variable-speed condensing gas furnace. On multi-stage furnaces, this switch verifies that the inducer motor is generating the correct negative pressure for its firing stage before the board energizes the igniter and gas valve. When venting, condensate, or the inducer is compromised, this switch keeps the burners off — the root of many \"pressure switch failed to close\" fault codes.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 0130F00100\u003c\/li\u003e\n\u003cli\u003eType: Air-proving \/ draft pressure switch (multi-stage rated)\u003c\/li\u003e\n\u003cli\u003eFunction: Confirms inducer draft pressure prior to ignition\u003c\/li\u003e\n\u003cli\u003eConnection: Hose port to collector box\/inducer, spade terminals\u003c\/li\u003e\n\u003cli\u003eCompatibility: Goodman ACVC950915DXAC and compatible Goodman\/Amana furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe trip setpoint, measured in inches of water column, is critical to safe operation. The \u003cstrong\u003egenuine OEM 0130F00100\u003c\/strong\u003e is factory-calibrated for the ACVC95 platform. Generic equivalents frequently carry a different setpoint, causing nuisance lockouts or — more dangerously — masking real venting problems.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2\/5).\u003c\/strong\u003e Disconnect power, pull the hose and spade terminals, remove the mounting screws, and install the OEM switch. Match the pressure rating exactly. If lockouts continue, check the vent pipe, condensate trap, and inducer assembly for restrictions before assuming the switch is faulty.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Direct Replacement","offer_id":63032467685747,"sku":"0130F00100-GEN","price":42.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048294334835,"sku":"0130F00100","price":55.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-pressure-switch-dual-0130F00100.jpg?v=1782950023","url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-pressure-switch-for-acvc950915dxac-furnace-0130f00100","provider":"National HVAC Parts","version":"1.0","type":"link"}