{"product_id":"oem-goodman-pressure-switch-for-acvc950714cxba-furnace-0130f00070-1","title":"OEM Goodman Pressure Switch for ACVC950714CXBA Furnace — 0130F00070","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00070\u003c\/strong\u003e is a genuine OEM air pressure switch for the \u003cstrong\u003eACVC950714CXBA\u003c\/strong\u003e condensing gas furnace and compatible Goodman\/Amana models. The pressure switch proves that the inducer (draft) motor has created adequate negative pressure to safely vent combustion gases before the control board allows ignition. If it doesn't sense the correct draft — due to a weak inducer, blocked vent, plugged condensate trap, or cracked hose — it keeps the gas valve closed and the furnace will not fire, often throwing a pressure-switch fault (e.g., Code 31) or going into lockout.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0130F00070\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Negative-pressure (draft proving) switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Verifies inducer draft before ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Single-stage \/ pressure-tap specific\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits Model:\u003c\/strong\u003e ACVC950714CXBA (and compatible Goodman\/Amana furnaces)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003ePressure switches are matched to an exact set point (measured in inches of water column). The \u003cstrong\u003egenuine OEM 0130F00070\u003c\/strong\u003e carries the correct trip pressure and port configuration for this furnace. A generic switch with the wrong set point can either nuisance-trip on a healthy unit or fail to protect against a genuine venting problem — both unacceptable on a combustion safety.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2 of 5).\u003c\/strong\u003e Around 15 minutes. Cut power, photograph and transfer the wires and the rubber sensing hose to the new switch, then mount it. Confirm the hose is clear and the trap is clean so the new switch isn't fighting a real draft problem. Verify model\/serial compatibility before installing.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057484382579,"sku":"GOODMAN-2773","price":18.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-pressure-switch-for-acvc950714cxba-furnace-0130f00070-1","provider":"National HVAC Parts","version":"1.0","type":"link"}