{"product_id":"oem-goodman-pressure-switch-for-acvc950714cxad-0130f00070","title":"OEM Goodman Pressure Switch for ACVC950714CXAD — 0130F00070","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0130F00070 Pressure Switch\u003c\/strong\u003e is a genuine OEM draft-proving safety control for the Goodman\/Amana \u003cstrong\u003eACVC950714CXAD\u003c\/strong\u003e condensing gas furnace. It verifies that the inducer motor is pulling proper draft and that the venting is clear before the control board energizes the igniter and opens the gas valve. If it can't sense adequate negative pressure, ignition is blocked — a critical protection against flue blockage and improper combustion.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0130F00070\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Negative-pressure (vacuum) draft-proving switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Proves inducer draft \/ vent flow before ignition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Hose port to inducer housing, spade terminals to board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits Model:\u003c\/strong\u003e ACVC950714CXAD and compatible Goodman\/Amana furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOEM vs. Generic:\u003c\/strong\u003e Pressure switches are rated to a specific actuation point measured in inches of water column (\"WC). The OEM 0130F00070 is set to the exact pressure spec for the ACVC9 inducer and vent design. A mismatched generic switch can keep the furnace from starting or, worse, allow it to fire under poor-draft conditions. Stick with the factory-rated part.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstall Difficulty:\u003c\/strong\u003e Easy (1\/5). Cut power, pull the rubber sensing hose, unplug the two terminals, remove the mounting screws, and reverse. Inspect the hose and inducer port for soot or condensate while you're in there. About 15 minutes.\u003c\/p\u003e\u003cp\u003eResolve pressure-switch lockout codes and restore reliable ignition with this genuine Goodman replacement.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Direct Replacement","offer_id":63032464146803,"sku":"0130F00070-GEN","price":13.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048294105459,"sku":"0130F00070","price":18.13,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-0130F00070_5f242e7b-1ba4-42c5-8298-7ed720a28f4e.jpg?v=1782950010","url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-pressure-switch-for-acvc950714cxad-0130f00070","provider":"National HVAC Parts","version":"1.0","type":"link"}