{"product_id":"oem-goodman-manual-reset-limit-switch-for-gks90703bxah-10123533","title":"OEM Goodman Manual Reset Limit Switch for GKS90703BXAH — 10123533","description":"\u003ch2\u003eGoodman 10123533 Manual Reset Limit Switch\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003e10123533\u003c\/strong\u003e is a genuine OEM Goodman \u003cstrong\u003emanual reset high-limit safety switch\u003c\/strong\u003e and a direct-fit replacement for the \u003cstrong\u003eGKS90703BXAH\u003c\/strong\u003e gas furnace. This thermal safety device opens the control circuit if the heat exchanger or burner area exceeds its rated temperature, shutting the furnace down to prevent overheating. Because it is a manual-reset design, it must be physically reset with the button after a fault is cleared — a tripped switch is a signal to inspect airflow, filters, and the heat exchanger.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart number: 10123533\u003c\/li\u003e\n\u003cli\u003eType: manual reset high-limit \/ rollout switch\u003c\/li\u003e\n\u003cli\u003eAction: normally closed, opens on high temperature\u003c\/li\u003e\n\u003cli\u003eEquipment: Goodman gas furnace\u003c\/li\u003e\n\u003cli\u003eFits model: GKS90703BXAH\u003c\/li\u003e\n\u003cli\u003eTerminals: 1\/4 in quick-connect spades\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003eOEM switch\u003c\/strong\u003e is set to the precise trip temperature engineered for the GKS90703BXAH cabinet. Generic limit switches with the wrong temperature rating can nuisance-trip or, worse, fail to protect the furnace. The OEM part ensures correct calibration, mounting footprint, and terminal placement.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy.\u003c\/strong\u003e Typically a 10–15 minute repair: disconnect power, unplug the two spade wires, remove the mounting screws, install the new switch in the same orientation, and reconnect. Press the reset button after wiring. Before returning the furnace to service, replace a dirty filter and confirm the blower and inducer run freely, since restricted airflow is the usual cause of a tripped limit.\u003c\/p\u003e\u003cp\u003eAlways disconnect power before servicing. Repeated trips indicate an underlying airflow or heat-exchanger problem that should be diagnosed by a technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058090754419,"sku":"GOODMAN-10666","price":9.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-manual-reset-limit-switch-for-gks90703bxah-10123533","provider":"National HVAC Parts","version":"1.0","type":"link"}