{"product_id":"oem-goodman-manual-reset-limit-switch-for-gch950703bxab-10123517","title":"OEM Goodman Manual Reset Limit Switch for GCH950703BXAB — 10123517","description":"\u003ch2\u003eOEM Goodman 10123517 Manual Reset Limit Switch\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e10123517\u003c\/strong\u003e is the genuine OEM manual-reset high-limit \/ rollout safety switch for \u003cstrong\u003eGCH950703BXAB\u003c\/strong\u003e gas furnaces. This normally-closed thermal cutout opens if the heat exchanger or burner area exceeds its trip temperature, shutting off the furnace to prevent unsafe overheating. Because it is a \u003cem\u003emanual\u003c\/em\u003e reset, a tripped switch requires the button to be pressed to restore heat — and a switch that trips repeatedly signals an airflow or combustion issue that should be inspected.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 10123517\u003c\/li\u003e\n\u003cli\u003eComponent: Manual reset high-limit \/ rollout switch\u003c\/li\u003e\n\u003cli\u003eType: Normally closed (opens on temperature rise)\u003c\/li\u003e\n\u003cli\u003eReset: Manual push-button\u003c\/li\u003e\n\u003cli\u003eCompatible Model: GCH950703BXAB (GCH95 series)\u003c\/li\u003e\n\u003cli\u003eEquipment Type: Gas Furnace\u003c\/li\u003e\n\u003cli\u003eFit: Direct factory replacement — matches OEM terminal and mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e switch is calibrated to the exact trip and reset temperatures specified for the GCH95 heat exchanger. Generic limit switches with the wrong setpoint can trip prematurely or, worse, fail to protect against a real overheat. The OEM part guarantees correct, safe cutout behavior.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy–Moderate (2\/5).\u003c\/strong\u003e Disconnect power, note the wire terminals, remove the mounting screws, and transfer the wiring to the new switch. Typical time is 15–20 minutes. If the switch keeps tripping after replacement, have the furnace inspected for restricted airflow or flame rollout.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058061459827,"sku":"GOODMAN-9873","price":7.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-manual-reset-limit-switch-for-gch950703bxab-10123517","provider":"National HVAC Parts","version":"1.0","type":"link"}