{"product_id":"oem-goodman-manual-reset-limit-switch-for-amvc951155dxae-10123533","title":"OEM Goodman Manual Reset Limit Switch for AMVC951155DXAE — 10123533","description":"\u003ch2\u003eGenuine Goodman 10123533 Manual Reset Limit Switch\u003c\/h2\u003e\u003cp\u003eOEM part number \u003cstrong\u003e10123533\u003c\/strong\u003e is the manual-reset high-limit safety switch for the Goodman\/Amana \u003cstrong\u003eAMVC951155DXAE\u003c\/strong\u003e 96% AFUE gas furnace. This normally-closed thermal switch opens and cuts power to the gas valve if it senses an overheat or flame-rollout condition — protecting the heat exchanger, cabinet, and home from unsafe temperatures. Unlike an auto-reset limit, the manual-reset design stays open until physically reset, so a tripped switch flags a real fault that should be investigated. When the switch itself fails open or won't reset, the furnace won't fire, and the correct OEM replacement restores safe operation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 10123533\u003c\/li\u003e\n\u003cli\u003eComponent: Manual reset high-limit \/ rollout safety switch\u003c\/li\u003e\n\u003cli\u003eFits: Goodman \/ Amana AMVC951155DXAE furnace\u003c\/li\u003e\n\u003cli\u003eCategory: Limit switch \/ safety control\u003c\/li\u003e\n\u003cli\u003eType: Normally-closed thermal cutout, manual reset button\u003c\/li\u003e\n\u003cli\u003eEquipment Type: High-efficiency gas furnace\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eLimit switches are calibrated to a specific trip temperature and mounting footprint. A generic switch with the wrong setpoint or terminal orientation can nuisance-trip or, worse, fail to open when it should — defeating a critical safety function. The genuine 10123533 carries the exact factory trip rating and bracket for the AMVC951155DXAE, ensuring the furnace protects itself as designed.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2 of 5).\u003c\/strong\u003e Roughly a 15–20 minute repair. Shut off power and gas, disconnect the two wire leads, remove the mounting screws, and install the new switch in the same orientation. \u003cstrong\u003eImportant:\u003c\/strong\u003e if a limit switch tripped, diagnose the underlying cause (blocked airflow, dirty filter, failed blower, or cracked heat exchanger) before returning the furnace to service — a tripped safety is a symptom, not the root problem.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057993924979,"sku":"GOODMAN-8979","price":9.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-manual-reset-limit-switch-for-amvc951155dxae-10123533","provider":"National HVAC Parts","version":"1.0","type":"link"}