{"product_id":"oem-goodman-manual-reset-limit-switch-for-amh950905cxaa-10123517","title":"OEM Goodman Manual Reset Limit Switch for AMH950905CXAA — 10123517","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e10123517\u003c\/strong\u003e is a genuine OEM manual-reset high-limit switch built for the Amana\/Goodman \u003cstrong\u003eAMH950905CXAA\u003c\/strong\u003e gas furnace. This thermally-activated safety device opens the control circuit and shuts the furnace down if it senses an over-temperature or flame-rollout condition, protecting the heat exchanger and surrounding cabinet from heat damage. Because it is a \u003cstrong\u003emanual reset\u003c\/strong\u003e device, it stays open until physically reset — a deliberate design that forces a service check after a fault.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 10123517\u003c\/li\u003e\n\u003cli\u003eFunction: High-temperature \/ rollout safety limit\u003c\/li\u003e\n\u003cli\u003eReset Type: Manual (push-button)\u003c\/li\u003e\n\u003cli\u003eAction: Normally Closed, opens on rise\u003c\/li\u003e\n\u003cli\u003eFits: Amana\/Goodman AMH950905CXAA and compatible furnaces\u003c\/li\u003e\n\u003cli\u003eTerminals: 1\/4\" quick-connect spade\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM Goodman\u003c\/strong\u003e switch is matched to the exact trip temperature and bracket footprint your furnace requires, so it seats correctly and trips at the engineered set point. A \u003cstrong\u003eGeneric\u003c\/strong\u003e substitute can work for the same role at a lower cost but may differ in temperature rating or mounting tab orientation. For a safety cutoff, OEM is the safer choice.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1 of 5).\u003c\/strong\u003e With power off, unplug the two spade terminals, remove the mounting screws, and install the replacement in the same orientation. Takes about 10 minutes. If the switch had tripped, always diagnose the root cause (blocked flue, cracked heat exchanger, dirty filter) before returning the furnace to service.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057677091187,"sku":"GOODMAN-6521","price":7.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-manual-reset-limit-switch-for-amh950905cxaa-10123517","provider":"National HVAC Parts","version":"1.0","type":"link"}