{"product_id":"oem-goodman-low-pressure-switch-for-dcc300xxx4vvxcaa-0130m00087","title":"OEM Goodman Low Pressure Switch for DCC300XXX4VVXCAA — 0130M00087","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0130M00087 Low Pressure Switch\u003c\/strong\u003e is a genuine OEM safety control for the \u003cstrong\u003eDCC300XXX4VVXCAA\u003c\/strong\u003e packaged air conditioner. It senses suction-line refrigerant pressure and opens the 24V control circuit when pressure drops too low — protecting the compressor from running on a low charge, a refrigerant leak, restricted airflow, or a freeze-up. Using the factory-correct switch ensures the loss-of-charge protection trips at the precise pressure your equipment was designed around.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Low pressure \/ loss-of-charge cut-off (auto-reset, normally closed)\u003c\/li\u003e\n\u003cli\u003eCircuit: 24V low-voltage safety string\u003c\/li\u003e\n\u003cli\u003eConnection: 1\/4\" female spade terminals\u003c\/li\u003e\n\u003cli\u003eFitting: Suction-side refrigerant port\u003c\/li\u003e\n\u003cli\u003eFits: Goodman DCC300XXX4VVXCAA and related DCC300 series\u003c\/li\u003e\n\u003cli\u003eOEM Part: 0130M00087\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0130M00087\u003c\/strong\u003e guarantees the correct cut-out\/cut-in setpoints and a confirmed fit on the DCC300 platform. \u003cstrong\u003eGeneric low pressure switches\u003c\/strong\u003e are cheaper but often use different trip pressures and may need terminal or fitting adapters. For reliable freeze and loss-of-charge protection, OEM removes the guesswork.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (3\/5).\u003c\/strong\u003e The electrical side is simple spade-terminal work, but the switch ties into the sealed refrigerant system. A Schrader-port version swaps quickly; a brazed version requires EPA-certified recovery and recharge. Cut all power before working on the unit.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Direct Replacement","offer_id":63032326816115,"sku":"0130M00087-GEN","price":21.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048275526003,"sku":"0130M00087","price":28.54,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-pressure-switch-single-0130M00087_a42a8a49-e4de-4bb9-94a3-6414c58710e6.jpg?v=1782949314","url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-low-pressure-switch-for-dcc300xxx4vvxcaa-0130m00087","provider":"National HVAC Parts","version":"1.0","type":"link"}