{"product_id":"oem-goodman-low-pressure-switch-for-aph1624m41ab-heat-pump-0130m00075","title":"OEM Goodman Low Pressure Switch for APH1624M41AB Heat Pump — 0130M00075","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130M00075 Low Pressure Switch\u003c\/strong\u003e is a genuine OEM suction-side safety control designed for the \u003cstrong\u003eAPH1624M41AB\u003c\/strong\u003e heat pump. It monitors low-side refrigerant pressure and opens the compressor circuit when pressure falls below the safe threshold — guarding against loss-of-charge, a stuck metering device, or a frozen coil that would otherwise let the compressor run dry and slug. Symptoms of a failing low-pressure switch include short-cycling, a compressor that won't start in cold weather, or a loss-of-charge lockout code.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0130M00075\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Low-side \/ loss-of-charge cut-off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Auto-reset SPST switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment:\u003c\/strong\u003e Heat Pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits Model:\u003c\/strong\u003e APH1624M41AB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e 1\/4 in. quick-connect fitting, spade terminals\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM Goodman\u003c\/strong\u003e switch carries the precise low-pressure cut-out setpoint this system expects, so it protects the compressor without nuisance trips during normal low-ambient operation. Generic switches with the wrong setpoint either lock the unit out prematurely or fail to protect it at all. OEM keeps the safety window correct.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (3 of 5).\u003c\/strong\u003e Requires accessing the low-side port, transferring the spade terminals, and leak-checking the connection. About 30–45 minutes. Refrigerant-side service should be done by an EPA 608-certified technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058294833523,"sku":"GOODMAN-15778","price":22.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-low-pressure-switch-for-aph1624m41ab-heat-pump-0130m00075","provider":"National HVAC Parts","version":"1.0","type":"link"}