{"product_id":"oem-goodman-low-pressure-switch-for-aph1430m41ac-0130m00075","title":"OEM Goodman Low-Pressure Switch for APH1430M41AC — 0130M00075","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130M00075 Low-Pressure Switch\u003c\/strong\u003e is a genuine OEM safety control for the \u003cstrong\u003eAPH1430M41AC\u003c\/strong\u003e heat pump and compatible Goodman\/Amana units. Installed on the suction (low) side of the refrigerant circuit, it senses when pressure drops below the safe minimum — from a refrigerant leak, loss of charge, restricted metering device, or low ambient conditions — and opens the compressor circuit. This prevents the compressor from running under vacuum, which causes overheating, oil breakdown, and coil freeze-up.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0130M00075\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Low-pressure \/ loss-of-charge switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Model:\u003c\/strong\u003e APH1430M41AC (Goodman\/Amana heat pump)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Opens on low suction pressure; auto-reset on recovery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Low-side sensing port with quick-connect terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit:\u003c\/strong\u003e Direct OEM exact-fit replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003eOEM Goodman switch\u003c\/strong\u003e carries the correct factory low-side cut-out and cut-in setpoints for the APH platform. A generic switch with mismatched setpoints will either lock out the system on cold mornings or allow the compressor to run dangerously low on charge. OEM ensures proper protection and a sealed sensing connection.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIntermediate.\u003c\/strong\u003e Wiring terminals connect in minutes; opening the refrigerant port for the switch body requires recovery, evacuation, and recharge. EPA Section 608 certification recommended when the sealed system is breached.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058272092531,"sku":"GOODMAN-15368","price":22.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-low-pressure-switch-for-aph1430m41ac-0130m00075","provider":"National HVAC Parts","version":"1.0","type":"link"}