{"product_id":"oem-goodman-low-pressure-switch-for-aph1424h41de-0130m00075","title":"OEM Goodman Low Pressure Switch for APH1424H41DE — 0130M00075","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130M00075 Low Pressure Switch\u003c\/strong\u003e is a genuine OEM safety control for the \u003cstrong\u003eAPH1424H41DE\u003c\/strong\u003e package heat pump. Wired into the low\/suction side of the system, it opens the control circuit when suction pressure drops too low — the classic symptom of a refrigerant leak, loss of charge, or a restricted metering device. By shutting the compressor down before it runs under vacuum, this switch prevents the compressor from overheating and the evaporator from freezing solid. A failed switch will either lock the system out on a good charge or fail to protect the compressor during a real leak, so an exact OEM replacement is important.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0130M00075\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Low pressure (loss-of-charge) auto-reset switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit:\u003c\/strong\u003e Low\/suction side of the refrigerant loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e Goodman \/ Amana APH1424H41DE heat pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Opens control circuit on low suction pressure to protect the compressor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003efactory OEM switch\u003c\/strong\u003e carries the precise low-side cut-out and cut-in setpoints Goodman engineered for this unit. Substituting a generic switch with different thresholds undermines the very protection it's meant to provide. Match OEM for reliable, code-correct safety operation.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate.\u003c\/strong\u003e If your unit uses a Schrader-port switch, it can often be swapped without recovering the charge; brazed-in versions require EPA 608 recovery and evacuation. Confirm your fitting type before starting — brazed units are a licensed-technician job.\u003c\/p\u003e\u003cp\u003eShips as genuine Goodman\/Amana OEM stock. Confirm model and serial before ordering.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058270585203,"sku":"GOODMAN-15324","price":22.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-low-pressure-switch-for-aph1424h41de-0130m00075","provider":"National HVAC Parts","version":"1.0","type":"link"}