{"product_id":"oem-goodman-low-pressure-switch-for-aph1330h41ca-0130m00075","title":"OEM Goodman Low Pressure Switch for APH1330H41CA — 0130M00075","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0130M00075\u003c\/strong\u003e is a genuine OEM low-pressure switch built as a direct-fit replacement for the \u003cstrong\u003eAPH1330H41CA\u003c\/strong\u003e heat pump and compatible Goodman\/Amana units. This control monitors suction-side refrigerant pressure and opens the compressor circuit when pressure drops too low — protecting the compressor from running against a loss of charge, a slow refrigerant leak, or a frozen evaporator coil. It's a low-cost part that prevents very expensive compressor damage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Low-pressure \/ loss-of-charge safety switch\u003c\/li\u003e\n\u003cli\u003eFunction: opens compressor circuit on low suction pressure\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 0130M00075\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (Amana compatible)\u003c\/li\u003e\n\u003cli\u003eEquipment: Heat Pump — model APH1330H41CA\u003c\/li\u003e\n\u003cli\u003eFit: Direct OEM replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0130M00075\u003c\/strong\u003e is factory-calibrated to the correct cut-out and cut-in pressures for this system's refrigerant charge, and it uses the exact fitting and terminal connector. Generic substitutes frequently trip at incorrect set-points, causing intermittent no-cool\/no-heat lockouts that are hard to diagnose. For dependable compressor protection, match the OEM specification.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate to advanced\u003c\/strong\u003e — best performed by a licensed HVAC technician. Depending on whether the port is Schrader-style or brazed, service may require refrigerant recovery and EPA-compliant handling. Always kill power at the disconnect first. Typical job runs 30–45 minutes.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDisconnect power before servicing and confirm the OEM part number on your existing switch before ordering.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058267472243,"sku":"GOODMAN-0130M00075","price":22.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-low-pressure-switch-for-aph1330h41ca-0130m00075","provider":"National HVAC Parts","version":"1.0","type":"link"}