{"product_id":"oem-goodman-furnace-flame-sensor-for-acvc90905dxaa-0130f00010s-1","title":"OEM Goodman Furnace Flame Sensor for ACVC90905DXAA — 0130F00010S","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0130F00010S Flame Sensor\u003c\/strong\u003e is a genuine OEM replacement for the Goodman \u003cstrong\u003eACVC90905DXAA\u003c\/strong\u003e condensing gas furnace. The flame sensor uses flame rectification to confirm the burner has lit; when it becomes coated with oxide or carbon, the control board can no longer detect flame and shuts the gas valve — causing the classic symptoms of a furnace that lights briefly then shuts off, short-cycles, or fails to heat. Replacing a worn or fouled sensor restores reliable ignition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0130F00010S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Flame sensor (flame rectification rod)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Model:\u003c\/strong\u003e ACVC90905DXAA condensing furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Confirms burner flame to the ignition control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Ignition \/ flame sensing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe OEM 0130F00010S is built with the correct rod length, bracket geometry, and terminal so it mounts in the original location and reads flame current within Goodman's spec. Generic sensors often sit at the wrong position in the flame envelope or carry a different microamp signature, leading to intermittent lockouts. For a no-heat repair you only want to do once, factory-original is the right call.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (DIY-friendly).\u003c\/strong\u003e Roughly 15 minutes. Turn off power and gas, remove the burner-compartment screw holding the sensor, unplug the lead, and install the new 0130F00010S. Avoid touching the rod with bare fingers. Restore power and confirm a clean light and steady flame. If you are not comfortable working near the gas valve and burners, use a licensed HVAC technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057480876403,"sku":"GOODMAN-2698","price":32.34,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-furnace-flame-sensor-for-acvc90905dxaa-0130f00010s-1","provider":"National HVAC Parts","version":"1.0","type":"link"}