{"product_id":"oem-goodman-flame-sensor-for-gks90904cxaf-0130f00010s","title":"OEM Goodman Flame Sensor for GKS90904CXAF — 0130F00010S","description":"\u003ch2\u003eGoodman 0130F00010S Flame Sensor\u003c\/h2\u003e\u003cp\u003eThe genuine OEM Goodman \u003cstrong\u003e0130F00010S\u003c\/strong\u003e flame sensor is a direct-fit replacement for \u003cstrong\u003eGKS90904CXAF\u003c\/strong\u003e gas furnaces and compatible Goodman, Amana, and Daikin equipment. The flame sensor (flame rod) sits in the burner flame and uses flame rectification to confirm to the control board that the burners have actually lit. When the sensor is coated with oxide or has failed, the board sees no flame signal and shuts the gas valve within seconds — producing the classic symptom of a furnace that lights, runs for 3–7 seconds, then drops out and re-tries or locks out.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 0130F00010S\u003c\/li\u003e\n\u003cli\u003eType: Single-rod flame sensor (flame rectification)\u003c\/li\u003e\n\u003cli\u003eFunction: Proves burner flame to the ignition control\u003c\/li\u003e\n\u003cli\u003eEquipment: Gas furnace (Goodman GKS90904CXAF and compatible)\u003c\/li\u003e\n\u003cli\u003eMounting: Single screw with spade terminal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0130F00010S\u003c\/strong\u003e uses the correct rod length, bend, and mounting bracket so it seats precisely in the flame path for a strong microamp signal. Generic flame sensors often require bending the rod to position, which weakens the sense current and shortens service life. For reliable ignition, the OEM rod is the safer choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1 of 5).\u003c\/strong\u003e Cut power at the disconnect, pull the single spade wire, remove one screw, and swap the sensor. Before condemning an old sensor, try gently cleaning the rod with fine steel wool or a Scotch-Brite pad — if the furnace still short-cycles after cleaning, replace it with this OEM unit. Typical job time is 10 minutes.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058097340787,"sku":"GOODMAN-0130F00010S","price":26.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-flame-sensor-for-gks90904cxaf-0130f00010s","provider":"National HVAC Parts","version":"1.0","type":"link"}