{"product_id":"oem-goodman-flame-sensor-for-amvm970803bnaa-furnace-0130f00010s","title":"OEM Goodman Flame Sensor for AMVM970803BNAA Furnace — 0130F00010S","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00010S Flame Sensor\u003c\/strong\u003e is a genuine OEM flame-sensing rod for the \u003cstrong\u003eAMVM970803BNAA\u003c\/strong\u003e modulating gas furnace and compatible Goodman, Amana, and Daikin models. This sensor uses flame rectification: while the burner is lit, the ignition control passes a tiny microamp current through the flame to confirm the burner is actually firing. If the current is too weak — usually from a dirty, oxidized, or cracked rod — the control shuts the gas valve within seconds as a safety measure. A worn 0130F00010S is one of the most common causes of a furnace that \u003cstrong\u003eignites then shuts off (short cycling)\u003c\/strong\u003e or throws a no-flame-sensed lockout.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart type:\u003c\/strong\u003e Flame sensor \/ flame rectification rod\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM part number:\u003c\/strong\u003e 0130F00010S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits model:\u003c\/strong\u003e AMVM970803BNAA (AMVM97 series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Confirms burner flame via microamp current to ignition control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Single spade terminal, screw-mount bracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman (Amana\/Daikin compatible)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0130F00010S\u003c\/strong\u003e places the sensing rod at the precise position and angle in the flame envelope that this burner needs for a stable microamp signal. Generic bend-to-fit rods often read low or erratic, causing intermittent lockouts. The OEM part restores a clean, reliable flame signal the first time.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy–Moderate (2\/5).\u003c\/strong\u003e Turn off gas and power, remove one screw and the wire, and install the new rod — do not touch the ceramic insulator with bare fingers. Reassemble and confirm a steady flame signal (typically 2–6 µA) with a meter if available.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058004115827,"sku":"GOODMAN-0130F00010S","price":34.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-flame-sensor-for-amvm970803bnaa-furnace-0130f00010s","provider":"National HVAC Parts","version":"1.0","type":"link"}