{"product_id":"oem-goodman-flame-sensor-for-amvc800805cnab-furnace-0130f00010s","title":"OEM Goodman Flame Sensor for AMVC800805CNAB Furnace — 0130F00010S","description":"\u003ch2\u003eGoodman 0130F00010S Flame Sensor\u003c\/h2\u003e\u003cp\u003eThe genuine OEM Goodman \u003cstrong\u003e0130F00010S flame sensor\u003c\/strong\u003e is the flame-rectification rod for the \u003cstrong\u003eAMVC800805CNAB\u003c\/strong\u003e 80% AFUE two-stage furnace. It confirms the burner has lit by passing a small microamp current through the flame; when that signal weakens from oxidation or carbon buildup, the control board can no longer prove flame and shuts the gas valve. The classic symptom is a furnace that lights, runs a few seconds, then drops out and re-tries — repeated short-cycling and eventual lockout. Installing a clean OEM sensor is the most common fix for flame-loss faults.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 0130F00010S\u003c\/li\u003e\n\u003cli\u003eCategory: Flame Sensor \/ Ignition\u003c\/li\u003e\n\u003cli\u003eCompatible Model: AMVC800805CNAB (Goodman\/Amana 80% two-stage furnace)\u003c\/li\u003e\n\u003cli\u003eType: Single-rod flame rectification sensor with ceramic insulator\u003c\/li\u003e\n\u003cli\u003eFit Type: Direct OEM replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0130F00010S\u003c\/strong\u003e uses the correct rod length, bend, and insulator rating so the sensing rod sits properly in the flame envelope. Generic rods that sit too high or low give erratic microamp readings and can mimic the very fault you are trying to fix. For a sensing component, the factory geometry matters.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — typically one screw and a single spade connector. Shut off power, remove the old sensor, seat the new one, and reconnect. Do not sand a brand-new sensor. Verify a steady flame and no short-cycling on the first heat call.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057853645171,"sku":"GOODMAN-7991","price":34.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-flame-sensor-for-amvc800805cnab-furnace-0130f00010s","provider":"National HVAC Parts","version":"1.0","type":"link"}