{"product_id":"oem-goodman-flame-sensor-for-amv80704bxba-furnace-0130f00010s","title":"OEM Goodman Flame Sensor for AMV80704BXBA Furnace — 0130F00010S","description":"\u003ch2\u003eGoodman 0130F00010S Flame Sensor\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e0130F00010S\u003c\/strong\u003e is a genuine OEM flame sensor (flame rod) for \u003cstrong\u003eGoodman\/Amana AMV80704BXBA\u003c\/strong\u003e 80% variable-speed gas furnaces. The sensor uses flame rectification to confirm the burners actually lit after ignition; if it doesn't detect a flame, the control board closes the gas valve and locks out for safety. A corroded, cracked, or fouled flame sensor is one of the most common causes of furnace \u003cstrong\u003eshort cycling\u003c\/strong\u003e and repeated ignition lockouts — often mistaken for a bad igniter or control board.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0130F00010S (OEM Goodman\/Amana)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Flame sensor \/ rectification rod\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Flame proving for burner safety lockout\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElement:\u003c\/strong\u003e Kanthal-style sensing rod with ceramic insulator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Single quick-connect terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e AMV80704BXBA and compatible Goodman\/Amana furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSold:\u003c\/strong\u003e Each\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0130F00010S\u003c\/strong\u003e matches the exact rod length, position, and insulator geometry needed to generate a strong, stable microamp signal for this furnace's control board. Generic sensors may read weak or intermittent, causing the very lockouts you're trying to fix. For reliable flame proving, OEM is recommended.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1 of 5).\u003c\/strong\u003e Power down the furnace, unplug the single sensor wire, remove one mounting screw, and install the new rod (avoid touching the sensing tip with bare fingers). No tools beyond a nut driver. A flame-signal (microamp) check after startup confirms proper operation.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eCompatibility note: verify your model and part number before ordering. Fits Goodman and Amana equipment.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057805148531,"sku":"GOODMAN-7614","price":39.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-flame-sensor-for-amv80704bxba-furnace-0130f00010s","provider":"National HVAC Parts","version":"1.0","type":"link"}