{"product_id":"oem-goodman-flame-sensor-for-amh81155cnac-furnace-0130f00010s","title":"OEM Goodman Flame Sensor for AMH81155CNAC Furnace — 0130F00010S","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00010S Flame Sensor\u003c\/strong\u003e is a genuine OEM flame rod for the \u003cstrong\u003eAMH81155CNAC\u003c\/strong\u003e gas furnace and compatible Goodman\/Amana models. The flame sensor confirms the burners have lit by carrying a tiny rectified microamp current through the flame. When the sensor is coated or corroded, the control board can't verify flame and shuts the gas valve — causing the furnace to light briefly then short cycle.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0130F00010S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Flame sensor \/ flame rectification rod\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElement:\u003c\/strong\u003e Kanthal sensing rod, ceramic-insulated base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal:\u003c\/strong\u003e Microamp flame-rectification current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e AMH81155CNAC and related Goodman\/Amana furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003eOEM Goodman flame sensor\u003c\/strong\u003e is built to the correct rod length and mounting angle so the tip sits properly in the flame envelope, producing a strong, stable microamp signal. Generic sensors with the wrong rod geometry can read weak flame current and trigger nuisance lockouts. For consistent, safe operation, OEM matters.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Shut off power, remove the single mounting screw, disconnect the wire, and swap in the new sensor. Route the rod so it crosses the burner flame without touching metal. If you're troubleshooting short cycling, try gently cleaning the old rod with fine emery cloth first — but a corroded sensor should simply be replaced.\u003c\/p\u003e\u003cp\u003eAll parts are sold new. Verify your model and serial number before ordering.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057643700595,"sku":"GOODMAN-6019","price":26.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-flame-sensor-for-amh81155cnac-furnace-0130f00010s","provider":"National HVAC Parts","version":"1.0","type":"link"}