{"product_id":"oem-goodman-flame-sensor-for-amh80704bxca-0130f00010s","title":"OEM Goodman Flame Sensor for AMH80704BXCA — 0130F00010S","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0130F00010S Flame Sensor\u003c\/strong\u003e is a genuine OEM flame-rectification rod for the \u003cstrong\u003eAMH80704BXCA\u003c\/strong\u003e gas furnace and compatible Goodman and Amana models. Positioned in the burner flame, the sensor confirms to the control board that ignition has occurred by conducting a small microamp current through the flame. When the rod becomes oxidized or cracked, the board can no longer prove flame and shuts the burners down — the classic symptom of a furnace that lights, runs briefly, then short-cycles or locks out.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Flame sensor \/ flame rectification rod\u003c\/li\u003e\n\u003cli\u003eFunction: Proves burner flame via microamp signal\u003c\/li\u003e\n\u003cli\u003eTerminal: 1\/4 in. quick-connect spade\u003c\/li\u003e\n\u003cli\u003eMount: Single-screw burner-box mount\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 0130F00010S\u003c\/li\u003e\n\u003cli\u003eFits: Goodman \/ Amana AMH80704BXCA and related gas furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe OEM 0130F00010S uses the correct rod length, alloy, and mounting geometry so it sits precisely in the flame envelope and returns a strong, stable signal to the control board. Generic sensors that sit too shallow or use inferior metal produce weak flame current and recurring lockouts. For a reliable ignition sequence, the genuine OEM sensor is the best value.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Turn off power, unplug the single spade wire, remove one screw, and install the new sensor in the same position. Takes about 10 minutes. Tip: after installing, gently clean any handling residue with a fine abrasive pad and confirm the rod is fully in the flame path. Most call-backs are simply a dirty sensor — but a cracked or corroded rod requires replacement.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057613848947,"sku":"GOODMAN-5389","price":29.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-flame-sensor-for-amh80704bxca-0130f00010s","provider":"National HVAC Parts","version":"1.0","type":"link"}