{"product_id":"oem-goodman-flame-sensor-for-acss960603bnaa-furnace-0130f00010s-1","title":"OEM Goodman Flame Sensor for ACSS960603BNAA Furnace — 0130F00010S","description":"\u003ch2\u003eGoodman 0130F00010S Flame Sensor\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e0130F00010S flame sensor\u003c\/strong\u003e is a genuine OEM flame-rectification rod for the Goodman \u003cstrong\u003eACSS960603BNAA\u003c\/strong\u003e 96% AFUE gas furnace and compatible Goodman\/Amana models. The flame sensor confirms the burner has lit by conducting a microamp rectified-flame signal back to the control board; when it oxidizes or fails, the furnace short-cycles or locks out on ignition. Replacing it is the most common fix for a furnace that lights then shuts off after a few seconds.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Flame-rectification sensor rod\u003c\/li\u003e\n\u003cli\u003eFunction: Proves burner flame to the ignition control\u003c\/li\u003e\n\u003cli\u003eSignal: Microamp rectified flame current\u003c\/li\u003e\n\u003cli\u003eFits: Goodman ACSS960603BNAA and compatible furnaces\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (OEM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe OEM 0130F00010S uses the correct rod alloy, length, and bracket geometry so it sits properly in the flame path and returns a strong signal. Generic sensors can read weak, causing intermittent lockouts. The genuine part restores dependable ignition the first time.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2\/5).\u003c\/strong\u003e Power off, remove one mounting screw, unplug the wire, and swap. Light cleaning is sometimes a temporary fix, but a corroded rod should be replaced. A 5-minute job for most homeowners.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057461838195,"sku":"GOODMAN-2407","price":32.34,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-flame-sensor-for-acss960603bnaa-furnace-0130f00010s-1","provider":"National HVAC Parts","version":"1.0","type":"link"}