{"product_id":"oem-goodman-condensate-drain-trap-for-gcv90704cxba-furnace-20171701","title":"OEM Goodman Condensate Drain Trap for GCV90704CXBA Furnace — 20171701","description":"\u003ch2\u003eGoodman 20171701 Condensate Drain Trap\u003c\/h2\u003e\u003cp\u003eThe Goodman 20171701 is a genuine OEM condensate drain trap engineered for the \u003cstrong\u003eGCV90704CXBA\u003c\/strong\u003e 92%+ AFUE gas furnace and compatible GCV90-series models. In a high-efficiency condensing furnace, the drain trap captures acidic condensate from the secondary heat exchanger and inducer while maintaining a water seal that blocks flue gases from escaping into the drain line. A cracked, clogged, or dried-out trap is a leading cause of pressure-switch lockout faults and nuisance shutdowns.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20171701\u003c\/li\u003e\n\u003cli\u003eComponent: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eFits: Goodman GCV90704CXBA and compatible GCV90-series furnaces\u003c\/li\u003e\n\u003cli\u003eEquipment: High-efficiency (condensing) gas furnace\u003c\/li\u003e\n\u003cli\u003eMaterial: Corrosion-resistant molded polymer\u003c\/li\u003e\n\u003cli\u003eFunction: Condensate drainage with flue-gas water seal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis genuine Goodman part matches factory port spacing, barb sizing, and trap geometry exactly, ensuring a proper seal and correct pressure-switch operation. Generic universal traps often require adapters, may not hold the correct water column, and can trigger persistent error codes. For reliable, code-compliant condensate handling we recommend the OEM 20171701.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2\/5).\u003c\/strong\u003e A typical replacement takes 15–30 minutes with basic hand tools. Power off the furnace, disconnect the drain hoses, remove the old trap, prime the new trap with water, and reconnect. No special tools required. If you are unsure about condensate routing, consult a licensed HVAC technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63058067685747,"sku":"GOODMAN-10065","price":20.95,"currency_code":"USD","in_stock":true}],"url":"https:\/\/nationalhvacparts.com\/products\/oem-goodman-condensate-drain-trap-for-gcv90704cxba-furnace-20171701","provider":"National HVAC Parts","version":"1.0","type":"link"}