{"product_id":"icp-x-13-ecm-blower-motor-for-wahm242a1-1-3-hp-module-ships-today","title":"ICP X-13 ECM Blower Motor for WAHM242A1 — 1\/3 HP Module | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM X-13 ECM blower motor control module (part number 1185281) is the 1\/3 HP variable-speed motor that drives the indoor blower wheel on the ICP WAHM242A1 air handler. The X-13 ECM is a constant-torque motor that holds steady airflow as filters load up and static pressure changes, delivering quieter operation and lower energy use than an old PSC motor. When it fails, the blower may not start, run at the wrong speed, short-cycle, or stop while the control board still calls for the fan. Bearing noise, intermittent operation, or no response to a fan call usually means the motor module has worn out.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1185281\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eX-13 ECM Constant-Torque Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndoor Blower \/ Air Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit replacement for the ICP \/ Tempstar \/ Heil WAHM242A1 air handler. The 1\/3 HP X-13 ECM platform is used across several ICP-family fan coil units, but confirm OEM part number 1185281 and your blower programming tap before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter before working on the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the high-voltage harness, 5-pin control plug, and tap selection before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug both connectors, loosen the blower wheel set screw, and pull the motor from the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Slide the new X-13 motor in, re-set the blower wheel position and set screw, and reconnect both plugs per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the blower ramps to the correct programmed speed on a fan call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlower won't start even though the board is calling for the fan\u003c\/li\u003e\n\u003cli\u003eMotor runs at the wrong speed or hunts up and down\u003c\/li\u003e\n\u003cli\u003eGrinding, squealing, or worn-bearing noise from the blower\u003c\/li\u003e\n\u003cli\u003eIntermittent operation or the motor cutting out under load\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021620003187,"sku":"1185281","price":246.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047760085363,"sku":"1185281-GEN","price":189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1185281_df0c8401-4285-4d9d-9855-849d105d7eaa.jpg?v=1782897118","url":"https:\/\/nationalhvacparts.com\/products\/icp-x-13-ecm-blower-motor-for-wahm242a1-1-3-hp-module-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}