{"product_id":"icp-x-13-ecm-blower-motor-control-for-waxt364a1-1-2-hp-ships-today","title":"ICP X-13 ECM Blower Motor Control for WAXT364A1 — 1\/2 HP | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM ICP ECM X-13 motor control module (part number 1185287) is a 1\/2 HP constant-torque variable-speed blower motor used in ICP \/ Tempstar \/ Heil air handlers and furnaces. The X-13 is a programmed electronically commutated motor that holds a fixed torque across changing static pressure, delivering quieter, more efficient airflow than a standard PSC motor. When it fails you will see weak or no blower airflow, the motor cycling on and off, intermittent operation that worsens as the motor heats up, or a complete no-blow condition with the rest of the system calling for run.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1185287\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eECM X-13 Constant-Torque Blower Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFurnace \/ Air Handler Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThis 1\/2 HP X-13 ECM motor control is the factory blower motor for the ICP \/ Tempstar \/ Heil \u003cstrong\u003eWAXT364A1\u003c\/strong\u003e system and related ICP-family air handlers and furnaces using the X-13 platform. Verify part number 1185287 and the motor tap\/program plug against your existing unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter before servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the line-voltage harness, the 24V control tap plug, and the blower wheel position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the connectors, loosen the blower wheel set screw, and slide the old motor out of the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1185287 motor, reset the blower wheel position and set screw, and reconnect the power and control plugs per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify the blower ramps up smoothly and delivers full airflow on a call for fan or heat\/cool.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWeak, reduced, or no blower airflow.\u003c\/li\u003e\n\u003cli\u003eMotor hums or buzzes but will not start spinning.\u003c\/li\u003e\n\u003cli\u003eBlower cycles on and off or quits after warming up.\u003c\/li\u003e\n\u003cli\u003eLoud bearing noise, rattling, or a burning smell from the blower section.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021610238323,"sku":"1185287","price":246.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047759528307,"sku":"1185287-GEN","price":189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1185287_0bccc831-8e4d-495f-9b94-1490531170b4.jpg?v=1782897098","url":"https:\/\/nationalhvacparts.com\/products\/icp-x-13-ecm-blower-motor-control-for-waxt364a1-1-2-hp-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}