{"product_id":"icp-x-13-ecm-blower-motor-control-for-waxm184a1-1-3-hp-ships-today","title":"ICP X-13 ECM Blower Motor Control for WAXM184A1 – 1\/3 HP | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM X-13 ECM blower motor control (part number 1185268) rated at 1\/3 HP for the ICP\/Tempstar\/Heil WAXM184A1 air handler. The X-13 is a constant-torque electronically commutated motor that holds a programmed airflow across a range of static pressures, delivering quieter operation and lower energy use than a standard PSC motor. It drives the indoor blower wheel that moves conditioned air through the duct system. When this motor begins to fail you will typically see weak or no airflow, the blower stalling on startup, intermittent shutdowns, or error codes from the air handler control board. Because the X-13 carries its electronics on the motor endbell, a failed control module means the whole motor assembly must be replaced.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1185268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eX-13 ECM Constant-Torque Blower Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Class\u003c\/td\u003e\n\u003ctd\u003eElectronically Commutated (ECM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFurnace \/ Air Handler Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as the direct OEM replacement blower motor control for the ICP\/Tempstar\/Heil WAXM184A1 air handler. Always confirm the part number stamped on your existing motor before ordering, as ICP uses several X-13 variants across the WAXM and related families.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power at the breaker and verify zero voltage at the air handler with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the blower compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph all motor and harness connections, including the tap position on the X-13 control plug, before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Unplug the motor harness, loosen the blower wheel set screw, pull the motor and bracket from the housing, and transfer the wheel and band clamp to the new motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new X-13 motor in the bracket, reinstall the blower wheel, set the wheel spacing, and reconnect the harness exactly as photographed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power and verify the blower ramps to the correct speed and airflow on a call for heat and cool.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBlower runs weak, intermittently, or not at all\u003c\/li\u003e\n\u003cli\u003eMotor hums or stalls but will not start spinning\u003c\/li\u003e\n\u003cli\u003eSystem trips on high limit or throws a blower fault code\u003c\/li\u003e\n\u003cli\u003eBurning smell or visibly damaged motor control endbell\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021611090291,"sku":"1185268","price":245.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047759462771,"sku":"1185268-GEN","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1185268_432d912a-caa8-4113-9c71-e1f6566df46e.jpg?v=1782897096","url":"https:\/\/nationalhvacparts.com\/products\/icp-x-13-ecm-blower-motor-control-for-waxm184a1-1-3-hp-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}