{"product_id":"icp-x-13-ecm-blower-motor-control-for-wahm302a1-1-3-hp-ships-today","title":"ICP X-13 ECM Blower Motor Control for WAHM302A1 — 1\/3 HP | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM X-13 ECM blower motor control (part number 1185282) is the 1\/3 HP variable-speed indoor blower motor for your ICP WAHM302A1 air handler. The X-13 is a constant-torque electronically commutated motor (ECM) with an integrated control module that delivers quieter operation, programmed airflow taps, and significantly better efficiency than a standard PSC motor. When this motor fails you will typically lose all indoor airflow — no heating or cooling delivery — or experience a motor that hums but will not spin, ramps erratically, or shuts down on a thermal fault. A failed module, worn bearings, or burnt windings all warrant replacement with the correct OEM unit.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1185282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eX-13 ECM Constant-Torque Blower Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eIntegrated ECM Motor Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndoor Air Handler \/ Furnace Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the ICP WAHM302A1 air handler. Because ICP builds the Tempstar, Heil, Comfortmaker, and Arcoaire lines, this 1\/3 HP X-13 motor control fits comparable WAHM-series fan coils engineered around the same constant-torque ECM blower platform. Verify part number 1185282 and the blower wheel sizing against your existing motor before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter; ECM motors retain charge, so wait several minutes before handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the air handler blower-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the motor power harness, the control tap connector, and the blower wheel position on the shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harness and control connectors, loosen the blower wheel set screw, slide the wheel off, and unbolt the motor from its mount.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Transfer the blower wheel to the new motor at the same depth, bolt the motor in, and reconnect the power and control taps per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the blower ramps up smoothly and delivers airflow on a call for heat and cool.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo indoor airflow on any heating or cooling call.\u003c\/li\u003e\n\u003cli\u003eMotor hums or vibrates but will not start, or starts and stops repeatedly.\u003c\/li\u003e\n\u003cli\u003eLoud bearing noise, grinding, or rattling from the blower section.\u003c\/li\u003e\n\u003cli\u003eMotor overheats and trips on thermal protection, or the control module is visibly scorched.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021619446131,"sku":"1185282","price":245.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047759069555,"sku":"1185282-GEN","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1185282_386e7f0d-30db-4444-8bf0-07d576738aad.jpg?v=1782897080","url":"https:\/\/nationalhvacparts.com\/products\/icp-x-13-ecm-blower-motor-control-for-wahm302a1-1-3-hp-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}