{"product_id":"icp-transformer-for-wfml110c066a1-40va-120-24v-ships-today-1","title":"ICP Transformer for WFML110C066A1 — 40VA 120\/24V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM control transformer (part #1176944) is a direct replacement for ICP Tempstar Heil furnace model WFML110C066A1. It steps the incoming 120V line voltage down to the 24V control voltage that powers the thermostat, gas valve, igniter circuit, and control board. A failed transformer is one of the most common reasons a furnace goes completely dead — no thermostat display, no blower, no ignition sequence. Rated at 40VA, it supplies ample control current for the entire low-voltage circuit. Symptoms of failure include a blank thermostat, a buzzing or humming transformer, a burnt smell at the control box, or a blown low-voltage fuse that keeps recurring.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1176944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eControl Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for ICP Tempstar Heil model WFML110C066A1 and shared across many ICP-family gas furnaces and air handlers using the same 40VA 120\/24V control platform (Comfortmaker, Arcoaire, KeepRite). Always confirm the printed VA and voltage on your existing transformer before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace control\/burner service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all primary (120V) and secondary (24V) wire connections before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the line and low-voltage leads, then unbolt the transformer from the control bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new transformer, reconnect primary and secondary leads exactly per your photo, and confirm the ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify 24V across the secondary terminals and a normal call-for-heat sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBlank or dead thermostat with no display\u003c\/li\u003e\n\u003cli\u003eFurnace completely unresponsive to a call for heat\u003c\/li\u003e\n\u003cli\u003eRepeatedly blown 3A or 5A low-voltage fuse\u003c\/li\u003e\n\u003cli\u003eAudible buzzing, humming, or a burnt smell from the transformer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027240829299,"sku":"1176944","price":37.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047741276531,"sku":"1176944-GEN","price":28.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-transformer-control-1176944_dc6108b6-54f9-4d74-95f9-0bdeb5e7bbbb.jpg?v=1782896491","url":"https:\/\/nationalhvacparts.com\/products\/icp-transformer-for-wfml110c066a1-40va-120-24v-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}