{"product_id":"icp-transformer-for-wapl364a4-208-230v-to-24v-40va-ships-today","title":"ICP Transformer for WAPL364A4 — 208\/230V to 24V 40VA | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM control transformer (part #1172028) steps down 208\/230V line voltage to 24V control voltage with a 40VA rating, powering the low-voltage control circuit in your ICP WAPL364A4 system. The transformer feeds the thermostat, relays, contactor coil, and control board. When it fails, the entire 24V control circuit goes dead — the unit will not start even though line power is present. Common failure causes include a shorted secondary, voltage spikes, or an overloaded control circuit that burns the windings.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eStep-Down Control Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e208\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirectly fits the ICP \/ Heil \/ Tempstar WAPL364A4 and other units in the WAPL364 family using a 208\/230V to 24V 40VA control transformer. Always confirm the OEM part number on the existing transformer before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control panel service cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all primary and secondary wire connections before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the leads, then unscrew the transformer from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new transformer and reconnect the primary and secondary leads per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm 24V across the secondary terminals.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo 24V at the thermostat or control board\u003c\/li\u003e\n\u003cli\u003eUnit completely unresponsive with line power present\u003c\/li\u003e\n\u003cli\u003eBurnt smell or visible scorching on the transformer body\u003c\/li\u003e\n\u003cli\u003eRepeatedly blown low-voltage fuse or control circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021613613427,"sku":"1172028","price":31.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047733674355,"sku":"1172028-GEN","price":24.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-transformer-control-1172028_04653545-bb08-4cab-a0aa-98d7a850c210.jpg?v=1782896304","url":"https:\/\/nationalhvacparts.com\/products\/icp-transformer-for-wapl364a4-208-230v-to-24v-40va-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}