{"product_id":"icp-spark-ignitor-electrode-for-rgs213ltaa0aaaa-oem-direct-ignition-ships-today","title":"ICP Spark Ignitor Electrode for RGS213LTAA0AAAA — OEM Direct Ignition | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM ignitor electrode (part number 1179966) is the direct spark ignition component for the ICP Tempstar Heil RGS213LTAA0AAAA gas furnace. The electrode produces the high-voltage spark that lights the burner gas on each heat cycle and, in many setups, doubles as the flame-sensing rod that verifies ignition to the control board. A cracked insulator or eroded tip is a leading cause of intermittent no-heat service calls. Common symptoms include the furnace sparking but not lighting, ignition lockouts, flame-loss short-cycling, or ignition only after multiple attempts. A genuine OEM electrode restores the correct spark gap and reliable flame rectification.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eIgnitor Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDirect Spark Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the factory replacement for the ICP Tempstar Heil RGS213LTAA0AAAA gas furnace, and fits related RGS-series furnaces built on the same burner and ignition platform across ICP brands (Tempstar, Heil, Comfortmaker, Arcoaire). Verify your part number against the unit before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner\/control access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the electrode wire routing and the spark\/sense gap position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the high-voltage lead, remove the mounting screw, and lift the old electrode clear of the burner assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new electrode, confirm the spark gap aligns with the burner per the photo, and reconnect the ignition lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then verify clean ignition and stable flame sensing through a full heat cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks\/sparks but the burner fails to light.\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or no-heat calls.\u003c\/li\u003e\n\u003cli\u003eCracked ceramic insulator or visibly eroded electrode tip.\u003c\/li\u003e\n\u003cli\u003eFlame loss \/ short-cycling shortly after ignition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027319374195,"sku":"1179966","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047719256435,"sku":"1179966-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_6e0b06a8-e8c5-4f27-8f2b-e5bdf85cb3c1.jpg?v=1782895934","url":"https:\/\/nationalhvacparts.com\/products\/icp-spark-ignitor-electrode-for-rgs213ltaa0aaaa-oem-direct-ignition-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}