{"product_id":"icp-single-pole-contactor-for-yj042gb1-35a-24v-coil-ships-today","title":"ICP Single-Pole Contactor for YJ042GB1 — 35A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM single-pole definite purpose contactor (part number 1050839) for the ICP Tempstar Heil YJ042GB1 heat pump. The contactor is an electrically operated switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling or heating. It carries a 35-amp resistive rating across a single pole and is controlled by a 24-volt coil. When the contactor fails, the outdoor unit will not start, will chatter, or will weld closed and run continuously. Pitted, burned, or buzzing contacts are the most common reason a condensing unit stops responding to the thermostat.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1050839\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned as the factory replacement contactor for the ICP\/Tempstar\/Heil YJ042GB1 heat pump and other condensing units in the same family that use a 35A 24V single-pole control. Always confirm the contactor amperage and coil voltage against the part you are removing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit's electrical service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note the line, load, and 24V coil terminals, transfer wires one at a time, then unbolt the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to match your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in and the compressor and fan start on a thermostat call.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start even though the thermostat is calling\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or chattering from the contactor\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or melted contact points\u003c\/li\u003e\n\u003cli\u003eCompressor runs nonstop because contacts are welded closed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027189612915,"sku":"1050839","price":29.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047716569459,"sku":"1050839-GEN","price":22.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1050839_979fef38-e1a2-4279-910c-cad1c4151158.jpg?v=1782895829","url":"https:\/\/nationalhvacparts.com\/products\/icp-single-pole-contactor-for-yj042gb1-35a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}