{"product_id":"icp-single-pole-contactor-for-yg042gc1-25a-24v-coil-ships-today","title":"ICP Single-Pole Contactor for YG042GC1 — 25A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM single-pole definite purpose contactor (part number 1050699) for the ICP \/ Heil \/ Tempstar YG042GC1 heat pump. The contactor is the electromechanical switch that energizes the outdoor compressor and condenser fan motor whenever the thermostat calls for cooling or heating. A 24-volt signal from the control board pulls in the coil, closing the 25-amp line-voltage contacts and powering the unit. When the call ends, the spring-loaded armature drops out and disconnects the load. Because it cycles thousands of times per season, the contactor is one of the most common HVAC failure points — pitted, burned, or welded contacts and a chattering or open coil are typical end-of-life symptoms that cause hard starts, buzzing, or a completely dead outdoor unit.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1050699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, Single-Pole (1P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP\/Heil\/Tempstar YG042GC1 condensing unit and other Carrier-family outdoor units that originally used contactor 1050699. Always confirm the part number on your existing contactor before ordering.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control-box service panel on the condenser.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line and coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor\/fan won't start.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contacts.\u003c\/li\u003e\n\u003cli\u003eContacts stick closed so the unit runs even when the thermostat is satisfied.\u003c\/li\u003e\n\u003cli\u003eLoud chattering from the contactor when it tries to engage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027193414003,"sku":"1050699","price":33.8,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047716471155,"sku":"1050699-GEN","price":26.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1050699_8ea124fe-aeaf-463b-b463-6f8ac40849b1.jpg?v=1782895822","url":"https:\/\/nationalhvacparts.com\/products\/icp-single-pole-contactor-for-yg042gc1-25a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}