{"product_id":"icp-single-pole-contactor-for-yg030gc9-25a-24v-coil-ships-today","title":"ICP Single-Pole Contactor for YG030GC9 — 25A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole definite purpose contactor (part number 1050699) is the electrical switch that controls power to the compressor and condenser fan motor in your ICP \/ Tempstar \/ Heil YG030GC9 heat pump. When the thermostat calls for cooling or heating, the 24-volt control circuit energizes the contactor coil, pulling the contacts closed and sending line voltage to the outdoor unit. Rated at 25 amps with a 24V coil, it is built to handle the high inrush current of compressor startup. Failure symptoms include an outdoor unit that won't start, chattering or buzzing at the contactor, pitted or welded contacts, and a humming coil that fails to pull in.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1050699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \/ Heat Pump \/ Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the direct OEM replacement for the ICP Tempstar Heil YG030GC9 heat pump. This 1-pole 25A 24V contactor is also commonly used across many residential ICP-family condensing units and heat pumps that share the same control voltage and amperage rating. Always confirm the coil voltage (24V) and amp rating match your existing part before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical service panel from the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil wires; unscrew the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, then reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in cleanly on a cooling\/heating call with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit fails to start while the indoor blower runs\u003c\/li\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the contactor\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded-shut contacts\u003c\/li\u003e\n\u003cli\u003eCoil energizes but contacts won't pull in (or won't release)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027194069363,"sku":"1050699","price":37.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047716405619,"sku":"1050699-GEN","price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1050699_98ae16d2-c58d-44ec-8b8a-4a1b2d38a365.jpg?v=1782895820","url":"https:\/\/nationalhvacparts.com\/products\/icp-single-pole-contactor-for-yg030gc9-25a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}