{"product_id":"icp-single-pole-contactor-for-ye048g-35a-24v-coil-ships-today","title":"ICP Single-Pole Contactor for YE048G — 35A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM single-pole definite purpose contactor (part number 14306503) for the ICP \/ Tempstar \/ Heil YE048G heat pump. Rated at 35 amps with a 24-volt control coil, the contactor is the electromechanical switch that energizes the compressor and condenser fan motor each time the thermostat calls for cooling or heating. When the 24V coil is energized, the contacts close and pass line voltage to the outdoor unit; when the call ends, a spring opens the contacts. Over thousands of cycles the silver-alloy contacts pit, burn, or weld, and the coil can fail open. Common failure symptoms include a humming or chattering outdoor unit, a compressor that will not start, contacts that stay closed so the unit never shuts off, or visible arcing and burn marks across the contact points.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e14306503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e35 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as the factory replacement for the ICP YE048G outdoor heat pump and shared across many ICP-family condensing units sold under the Heil, Tempstar, and Comfortmaker brands. Always confirm your existing contactor is a 1-pole, 35A, 24V coil unit before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control panel cover on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wires and terminal positions before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect line, load, and 24V coil wires, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in on a cooling call and the compressor and fan run.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor will not start\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on inspection\u003c\/li\u003e\n\u003cli\u003eSystem runs continuously and will not shut off\u003c\/li\u003e\n\u003cli\u003eChattering or rapid clicking from the contactor when energized\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027196428659,"sku":"14306503","price":37.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047716274547,"sku":"14306503-GEN","price":28.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-14306503_7dbf5564-8d1c-43d9-9ed5-73a89ed261cd.jpg?v=1782895811","url":"https:\/\/nationalhvacparts.com\/products\/icp-single-pole-contactor-for-ye048g-35a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}