{"product_id":"icp-single-pole-contactor-for-wca3484gka2-30a-24v-coil-w-shunt-ships-today","title":"ICP Single-Pole Contactor for WCA3484GKA2 — 30A 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole definite purpose contactor (part number 1172472) is the electrically controlled switch that powers the compressor and condenser fan on your ICP\/Heil\/Tempstar WCA3484GKA2 air conditioning unit. When the thermostat calls for cooling, the 24V control circuit energizes the contactor coil, pulling the contacts closed to deliver line voltage to the compressor and outdoor fan motor. This contactor is rated for 30 amps, uses a 24-volt coil, and includes a shunt for reliable load handling. A failed contactor is one of the most common reasons an outdoor unit won't start: pitted or welded contacts, a burned-out coil, or chattering all point to replacement. Symptoms include a humming outdoor unit that never starts, intermittent cooling, or a unit that runs continuously because the contacts have welded shut.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eWith Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWCA3484GKA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirectly fits the ICP\/Tempstar\/Heil WCA3484GKA2 condensing unit. As a genuine OEM replacement, part 1172472 also services many related ICP-family WCA-series air conditioners that use a 1-pole 30A 24V contactor. Always verify your existing contactor's pole count, amp rating, and coil voltage against the failed unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and the breaker. Verify zero voltage across the contactor terminals with a multimeter before touching any wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service\/electrical panel to expose the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Take a clear photo of every wire and terminal position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1172472 contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and call for cooling; confirm the contacts pull in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but the compressor and fan won't start\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contactor\u003c\/li\u003e\n\u003cli\u003eContacts chatter or buzz instead of pulling in cleanly\u003c\/li\u003e\n\u003cli\u003eUnit runs nonstop because the contacts have welded shut\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027256754547,"sku":"1172472","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047715488115,"sku":"1172472-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_b1e74d18-1be0-497d-ad9f-f4bad2b86e32.jpg?v=1782895768","url":"https:\/\/nationalhvacparts.com\/products\/icp-single-pole-contactor-for-wca3484gka2-30a-24v-coil-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}