{"product_id":"icp-single-pole-30a-contactor-for-wch3182gkr2-24v-coil-with-shunt-ships-today","title":"ICP Single-Pole 30A Contactor for WCH3182GKR2 — 24V Coil with Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole definite purpose contactor (part #1172472) is the electrical switch that energizes the compressor and condenser fan in your ICP Heil Tempstar WCH3182GKR2 heat pump. Rated at 30 amps with a 24-volt coil and an integrated shunt, it closes when the thermostat calls for heating or cooling and passes line voltage to the outdoor unit. Contactors fail from arcing, pitted or welded contacts, and burned coils. Common symptoms include a humming or chattering outdoor unit, a compressor that will not start, contacts that stick closed so the unit never shuts off, or visible burning around the terminals.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 1-Pole with Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the direct OEM replacement for the ICP Heil Tempstar WCH3182GKR2 condensing unit. The same 1172472 contactor is shared across many ICP-family WCH-series heat pumps and air conditioners. Confirm your existing contactor is a 1-pole 30A 24V coil unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel from the condensing unit to expose the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the wires, then unscrew the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to its matching terminal per your photo, and confirm the 24V coil leads are landed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contactor pulls in and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud humming or buzzing from the outdoor unit when it tries to start\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on inspection\u003c\/li\u003e\n\u003cli\u003eCompressor and fan won't start even though 24V is present at the coil\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously because contacts are stuck closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027255148915,"sku":"1172472","price":35.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047714865523,"sku":"1172472-GEN","price":26.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_d4adb17a-466c-446c-ab9a-02abb922b316.jpg?v=1782895726","url":"https:\/\/nationalhvacparts.com\/products\/icp-single-pole-30a-contactor-for-wch3182gkr2-24v-coil-with-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}