{"product_id":"icp-hot-surface-igniter-wiring-kit-for-rgs150leba0aaaa-oem-ignitor-ships-today","title":"ICP Hot Surface Igniter \u0026 Wiring Kit for RGS150LEBA0AAAA — OEM Ignitor | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit for the ICP RGS150LEBA0AAAA includes the igniter (part 1171306) and its dedicated wiring harness kit (part 1188370). On a call for heat, the control board energizes the igniter; it glows red-hot and lights the burner gas, then the flame sensor confirms a flame. Hot surface igniters are brittle and degrade with every cycle — the silicon carbide or nitride element develops micro-cracks until it can no longer reach ignition temperature. Bundling the wiring kit ensures a clean, corrosion-free connection, since brittle or chafed igniter leads are a frequent cause of intermittent no-heat calls. Typical symptoms include no ignition, a furnace that clicks but never lights, and lockout after several failed ignition attempts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFurnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt for the ICP \/ Tempstar \/ Heil RGS150LEBA0AAAA package gas unit and related models using the same hot surface ignition system. Confirm the igniter mounting and connector match your existing part.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas, disconnect power, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner\/service panel to reach the igniter at the burner assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the wiring connector and unscrew the brittle old igniter — handle by the base, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then connect the new wiring kit and route it clear of hot surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat call, and verify the igniter glows and lights the burners promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo ignition — burners never light on a heat call\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weakly\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027393855859,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047609614707,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_e8cd33ea-653f-459c-ae65-3c28ca2618fe.jpg?v=1782891550","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-wiring-kit-for-rgs150leba0aaaa-oem-ignitor-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}