{"product_id":"icp-hot-surface-igniter-kit-for-rgs150heaa0agaa-oem-with-wiring-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150HEAA0AGAA — OEM with Wiring | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM hot surface igniter (part number 1171306) with the matching igniter wiring kit (1188370) for the ICP \/ Tempstar \/ Heil RGS150HEAA0AGAA gas furnace. On each heat call, the control board sends line voltage to the igniter, which glows red-hot to ignite the burner gas. Hot surface igniters are brittle and wear out from thermal cycling; a cracked or open igniter is the most common cause of no-heat lockouts. The included wiring kit lets you renew the harness and connector at the same time, which is recommended since heat and vibration degrade the original leads. Replace at the first sign of failure to restore reliable ignition.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + igniter wiring kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP RGS150HEAA0AGAA and related ICP, Tempstar, Heil, and Comfortmaker gas furnaces using the same hot surface ignition system. Confirm the igniter part number and connector style against your unit before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power to the furnace and shut off the gas. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position, mounting screw, and harness routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw. Handle the igniter only by its ceramic base — never touch the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter in the same position, install the new wiring kit, and connect the harness. Keep fingers off the silicon-carbide element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners within the normal trial-for-ignition period.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace fails to ignite \/ no-heat lockout\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow on a heat call\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or white spots on the element\u003c\/li\u003e\n\u003cli\u003eRepeated ignition retries before the burner lights\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027430916467,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690748275,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_76580bc3-b141-4443-87a6-ce56d9b2fdba.jpg?v=1782894163","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-kit-for-rgs150heaa0agaa-oem-with-wiring-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}