{"product_id":"icp-hot-surface-igniter-kit-for-rgs102ltbb0aaa-oem-1171306-w-wiring-ships-today","title":"ICP Hot Surface Igniter Kit for RGS102LTBB0AAA — OEM 1171306 w\/ Wiring | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter kit includes the igniter (part 1171306) and its dedicated wiring kit\/harness (part 1188370) for ICP, Heil, and Tempstar gas furnaces. The hot surface igniter (HSI) is a resistive element that the control board energizes at the start of each heating cycle; it glows orange-hot and ignites the gas as it leaves the burners. Igniters are a leading cause of no-heat calls because the element is brittle and degrades with every cycle — it eventually cracks, develops hairline fractures, or loses the ability to reach ignition temperature. The included wiring kit ensures a clean, properly terminated connection back to the control board. Handle the new igniter only by its ceramic base; skin oils on the element can shorten its life.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar (OEM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness\/kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit replacement for ICP\/Tempstar\/Heil model RGS102LTBB0AAA and related RGS-series furnaces using igniter 1171306. Match the igniter mounting and connector against your existing part before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position, orientation, and wiring before removing it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old igniter without striking the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter by its ceramic base only, route and connect the new wiring kit, and confirm correct alignment over the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heating cycle, and verify the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo heat — burners never ignite on a call\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weakly\u003c\/li\u003e\n\u003cli\u003eVisible cracks, white spots, or breaks in the element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027633389939,"sku":"1171306","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047685964147,"sku":"1171306-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_c4266f1b-4b37-45ea-8fbe-da5ddfc843fd.jpg?v=1782893840","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-kit-for-rgs102ltbb0aaa-oem-1171306-w-wiring-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}