{"product_id":"icp-hot-surface-igniter-kit-for-rgs102ltab0aaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS102LTAB0AAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit for the ICP\/Heil\/Tempstar RGS102LTAB0AAA gas furnace includes the igniter element (Part No. 1171306) and the matched wiring kit (Part No. 1188370). On each call for heat, the furnace control board energizes the igniter, which glows to roughly 2,500°F and lights the gas at the burners. The hot surface igniter is one of the most common furnace failure points because the brittle silicon-carbide or silicon-nitride element degrades with every heating cycle. Symptoms of a failed igniter include no heat, a furnace that clicks and tries to light but never produces flame, a visibly cracked or dark igniter that never glows, or a unit that locks out after several failed ignition attempts. The included wiring kit ensures a clean, correct electrical connection during replacement.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt as the factory replacement for the ICP\/Heil\/Tempstar RGS102LTAB0AAA gas furnace. Because hot surface igniters are mounting- and connector-specific, the included wiring kit makes this a complete drop-in service part for the matched model. Verify the igniter mounting bracket and connector against your existing part before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power to the furnace and verify zero voltage with a multimeter; shut off the gas supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and its wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw. Handle by the ceramic base only — never touch the glowing element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the wiring kit, and seat the connector firmly. Do not touch the element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the trial period.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat; furnace tries to light but never ignites.\u003c\/li\u003e\n\u003cli\u003eIgniter never glows or glows weakly.\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or dark spots on the element.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027633652083,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047685931379,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_89e08a25-8f12-47ed-8a0f-6a2be2452cbc.jpg?v=1782893838","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-kit-for-rgs102ltab0aaa-with-wiring-harness-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}