{"product_id":"icp-hot-surface-igniter-kit-for-rgs102leca0aaa-oem-1171306-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS102LECA0AAA — OEM 1171306 with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit for the ICP \/ Tempstar \/ Heil RGS102LECA0AAA gas furnace includes the igniter (part number 1171306) and the matching igniter wiring kit (part number 1188370). On each heat call the control board sends voltage to the igniter, which glows red-hot to light the burners. Igniters are the most common gas-furnace failure point — the brittle silicon-carbide or silicon-nitride element cracks from thermal cycling, contamination, or being touched by bare hands, and a cracked element will not glow. The included wiring kit ensures a clean, factory-correct electrical connection and eliminates worn or heat-damaged leads. Symptoms of a failed igniter include no heat, the blower running cold, or a visible igniter that never glows during the ignition sequence.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS102LECA0AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the ICP RGS102LECA0AAA gas furnace and its Tempstar, Heil, and Comfortmaker equivalents. The bundled wiring kit matches the OEM connector so no splicing is required.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power to the furnace; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the igniter mounting screw, and carefully lift out the old igniter without touching the new element with bare hands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the supplied wiring kit, and route the harness clear of hot surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for heat, and confirm the igniter glows and the burners light on the first attempt.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat — burners never light\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow during the ignition sequence\u003c\/li\u003e\n\u003cli\u003eVisible cracks or chips in the igniter element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027636404595,"sku":"1171306","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047685407091,"sku":"1171306-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_c256da78-560e-4a2b-a350-51cbd727c2cd.jpg?v=1782893803","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-kit-for-rgs102leca0aaa-oem-1171306-with-wiring-harness-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}