{"product_id":"icp-hot-surface-igniter-for-wpg3302060lkb1-oem-1175974-igniter-assembly-ships-today-1","title":"ICP Hot Surface Igniter for WPG3302060LKB1 — OEM 1175974 Igniter Assembly | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM hot surface igniter assembly (part number 1175974) for the ICP\/Tempstar\/Heil WPG3302060LKB1 packaged gas furnace. The hot surface igniter glows red-hot on each call for heat to ignite the gas as it enters the burners. Repeated heating cycles slowly degrade the silicon-carbide or silicon-nitride element until it cracks and fails open. When that happens the furnace runs its inducer and gas-valve sequence but never lights, leaving you with cold air or a unit that locks out after several failed ignition attempts. Swapping a worn igniter is one of the most common no-heat repairs on this equipment and restores prompt, reliable ignition.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1175974\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWPG3302060LKB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the factory-correct igniter assembly for the ICP\/Tempstar\/Heil WPG3302060LKB1 packaged gas unit. Always confirm your existing part number and bracket orientation before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the unit disconnect and shut off the gas supply. Verify zero voltage with a multimeter before proceeding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace service \/ blower-compartment panel to reach the burner assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter bracket position and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness connector and remove the mounting screw(s). Handle the old igniter only by its ceramic base — never touch the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1175974 igniter in the same position, handling only the ceramic base, and reconnect the harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace runs the inducer but never lights the burners.\u003c\/li\u003e\n\u003cli\u003eUnit locks out after 3 failed ignition attempts (no glow visible).\u003c\/li\u003e\n\u003cli\u003eVisible cracks, blistering, or white deposits on the igniter element.\u003c\/li\u003e\n\u003cli\u003eIntermittent ignition — sometimes lights, sometimes drops to cold air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027223200115,"sku":"1175974","price":51.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047665189235,"sku":"1175974-GEN","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1175974_943265af-8cc7-4517-813c-63d7b90268dd.jpg?v=1782892937","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-wpg3302060lkb1-oem-1175974-igniter-assembly-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}