{"product_id":"icp-hot-surface-igniter-for-wfsr120d060a2-oem-furnace-ignition-kit-ships-today","title":"ICP Hot Surface Igniter for WFSR120D060A2 — OEM Furnace Ignition Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM ignition kit pairs the hot surface igniter (part number 1176919) with its mounting bracket (part number 1184324) for the ICP \/ Tempstar \/ Heil WFSR120D060A2 gas furnace. The hot surface igniter is a silicon-carbide or silicon-nitride element that glows red-hot on each call for heat to ignite the burner gas. It is the single most common furnace ignition failure point because the brittle element degrades with every heating cycle and eventually cracks. When it fails, the furnace inducer and gas valve sequence normally but the burners never light, leaving you with no heat. The matching bracket ensures correct positioning relative to the burner flame path.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1176919\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket Part Number\u003c\/td\u003e\n\u003ctd\u003e1184324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWFSR120D060A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM exact-fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP\/Tempstar\/Heil WFSR120D060A2 gas furnace. The same igniter and bracket also service the closely related WFSR120D060A1 revision. Verify against your furnace's parts list before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photo the igniter wiring and bracket position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, unscrew the bracket, and lift the assembly out — handle the element by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new bracket and igniter, never touching the element with bare fingers, and reconnect the harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition cycle to confirm the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace inducer runs but burners never ignite\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows orange\/white on a call for heat\u003c\/li\u003e\n\u003cli\u003eVisible cracks or white powdery flaking on the element\u003c\/li\u003e\n\u003cli\u003eIntermittent no-heat lockouts after several cycles\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021560168819,"sku":"1184324","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047662403955,"sku":"1184324-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1184324_63a281b4-1450-4be5-a94e-d418c627a743.jpg?v=1782892889","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-wfsr120d060a2-oem-furnace-ignition-kit-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}