{"product_id":"icp-hot-surface-igniter-for-wfar080c060b2-includes-igniter-bracket-ships-today","title":"ICP Hot Surface Igniter for WFAR080C060B2 — Includes Igniter Bracket | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (HSI) kit replaces the original ignition components in your ICP Tempstar\/Heil WFAR080C060B2 gas furnace. The kit includes OEM igniter \u003cstrong\u003e1176919\u003c\/strong\u003e and its mounting bracket \u003cstrong\u003e1184324\u003c\/strong\u003e. The hot surface igniter is the element that glows red-hot at the start of each heating cycle to ignite the gas at the burners. Because it cycles through extreme thermal stress on every call for heat, the silicon-carbide element is one of the most common furnace wear items. When it fails, the furnace will not light — you will typically hear the inducer and gas valve attempt to fire, but no flame or heat results. A cracked, pitted, or fully open igniter is the usual culprit behind no-heat service calls.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1176919 (Igniter), 1184324 (Bracket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWFAR080C060B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit Contents\u003c\/td\u003e\n\u003ctd\u003eIgniter + Mounting Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as a direct-fit replacement for the ICP Tempstar Heil WFAR080C060B2 gas furnace. These igniters are shared across many ICP-family (International Comfort Products) furnaces sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Always verify your existing part number against 1176919 before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring connector before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter and bracket. Handle the new igniter by the bracket only — never touch the element with bare fingers, as skin oils cause premature failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter and bracket in the same position, ensuring proper alignment over the burner, and reconnect the wiring per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then run a full heat cycle to confirm the igniter glows and the burners light cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs the inducer and clicks but never lights or produces heat\u003c\/li\u003e\n\u003cli\u003eIgniter element is cracked, blistered, or no longer glows\u003c\/li\u003e\n\u003cli\u003eContinuity test reads open (infinite resistance) across the igniter\u003c\/li\u003e\n\u003cli\u003eShort cycling or intermittent ignition during cold weather\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027247284595,"sku":"1184324","price":41.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047652082035,"sku":"1184324-GEN","price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1184324_01aebebb-9d5b-4cbb-8f0d-269b8aa1126a.jpg?v=1782892660","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-wfar080c060b2-includes-igniter-bracket-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}