{"product_id":"icp-hot-surface-igniter-for-wfar060a042a1-with-bracket-ships-today","title":"ICP Hot Surface Igniter for WFAR060A042A1 — With Bracket | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (part #1176919) and matching mounting bracket (part #1184324) ignite the burners on your ICP Tempstar Heil WFAR060A042A1 gas furnace. On a heat call, the control board energizes the igniter, which glows white-hot to light the gas at the burners. The igniter is the single most common furnace failure point because the brittle silicon-carbide element degrades with every heating cycle and eventually cracks. A failed igniter is the usual reason a furnace blows cold air, locks out on ignition failure, or short-cycles — the inducer and blower may run, but the burners never light. The included bracket ensures the element is positioned at the correct gap and angle to the burner for reliable ignition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1176919\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket Part Number\u003c\/td\u003e\n\u003ctd\u003e1184324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFactory replacement for the ICP Tempstar Heil WFAR060A042A1 gas furnace and compatible ICP-family furnaces using the same 120V hot surface igniter and bracket assembly. Handle the silicon-carbide element only by its ceramic base — skin oils shorten its life.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position, bracket alignment, and wire routing before removing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, unscrew the old igniter and bracket, and discard them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new bracket and igniter, set the correct gap to the burner, and reconnect the plug — never touch the element with bare hands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace blows cold air and never lights the burners\u003c\/li\u003e\n\u003cli\u003eSystem locks out and displays an ignition-failure code\u003c\/li\u003e\n\u003cli\u003eIgniter shows a visible crack or no longer glows\u003c\/li\u003e\n\u003cli\u003eRepeated short-cycling on the heat call\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027248365939,"sku":"1184324","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047650869619,"sku":"1184324-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1184324.jpg?v=1782892648","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-wfar060a042a1-with-bracket-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}