{"product_id":"icp-hot-surface-igniter-for-rgx060kmca0aaa-silicon-nitride-oem-1171306-ships-today","title":"ICP Hot Surface Igniter for RGX060KMCA0AAA — Silicon Nitride OEM 1171306 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (part number 1171306) is the factory ignition component for the ICP \/ Heil \/ Tempstar RGX060KMCA0AAA gas furnace. On each call for heat the control board sends 120V to the igniter, which glows to roughly 2,000°F and ignites the gas at the burners. Hot surface igniters are the single most common gas-furnace failure — the silicon nitride element is brittle and cracks from thermal cycling, vibration, or contamination from skin oils. When it fails, the draft inducer runs but the burners never light, leaving the home without heat and usually triggering an ignition-fault code on the board.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter (Silicon Nitride)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the exact-fit replacement for the ICP \/ Heil \/ Tempstar \/ Comfortmaker RGX060KMCA0AAA gas furnace. The same igniter is used across many RGX-series and related Heil-built furnace platforms. Confirm the part number and bracket orientation against your failed igniter before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter's bracket position and connector routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and withdraw the igniter — never touch the ceramic element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter in the same orientation, reseat the screw, and reconnect the plug per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat call, and confirm the igniter glows and the burners light within seconds.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInducer runs but burners never ignite — no heat.\u003c\/li\u003e\n\u003cli\u003eVisible crack, blister, or break in the ceramic element.\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all on a heat call.\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout fault code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027267797363,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047648903539,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-nitride-1171306_d68caace-2677-4bc7-a02f-83c03e924782.jpg?v=1782892594","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-rgx060kmca0aaa-silicon-nitride-oem-1171306-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}