{"product_id":"icp-hot-surface-igniter-for-rgs240heea0aaaa-120v-ships-today","title":"ICP Hot Surface Igniter for RGS240HEEA0AAAA — 120V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter electrode (OEM 1179966) lights the burners on your ICP \/ Heil \/ Tempstar RGS240HEEA0AAAA gas furnace. On each call for heat, the control board sends 120V to the igniter, which glows white-hot to ignite the gas as it leaves the burners. The igniter is one of the most frequently replaced furnace parts because the element is brittle and degrades with every heating cycle — thermal stress eventually cracks it. A furnace that clicks and tries to start but never produces heat, then locks out after several attempts, is the classic symptom of a cracked or burned-out igniter. Because the element is fragile, never touch its surface with bare fingers — skin oils create hot spots that shorten its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eSilicon Nitride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit replacement for the ICP \/ Heil \/ Tempstar \/ Comfortmaker RGS240HEEA0AAAA gas furnace and related platform models using the same burner ignition assembly. Confirm the connector style and mounting bracket match your original before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and remove the mounting screw(s); handle only by the ceramic base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, reconnect the harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace ignites no heat — clicks, tries, then locks out\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow when commanded\u003c\/li\u003e\n\u003cli\u003eVisible cracks, blisters, or breaks in the element\u003c\/li\u003e\n\u003cli\u003eIntermittent ignition or repeated lockout codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027313279347,"sku":"1179966","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047641956723,"sku":"1179966-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_3dcf14fc-86bd-42bf-b714-18bc18346b20.jpg?v=1782892462","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-rgs240heea0aaaa-120v-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}