{"product_id":"icp-hot-surface-igniter-for-rgs120leaa0agaa-with-wiring-kit-ships-today","title":"ICP Hot Surface Igniter for RGS120LEAA0AGAA with Wiring Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (part 1171306) ignites the burners on your ICP, Heil, and Tempstar RGS120LEAA0AGAA gas furnace. It is a line-voltage (120V) silicon-based element that glows red-hot on a heat call to light the main burner gas. When an igniter cracks, develops hairline fractures, or loses resistance, the furnace fails to light — producing no-heat calls, repeated lockouts, or a furnace that runs the inducer and waits but never fires. This listing includes the matching igniter wiring kit (part 1188370) so you can replace the harness and connector at the same time, which is the most common point of failure on aging igniters.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V line voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP\/Heil\/Tempstar RGS120LEAA0AGAA furnace and other RGS120 series units that originally shipped with igniter 1171306. Always confirm your existing igniter part number before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw(s), and lift the old igniter out without touching the new element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the included wiring kit, and reconnect per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and run a heat cycle; confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs the inducer and waits but never lights\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or hard lockout codes\u003c\/li\u003e\n\u003cli\u003eVisible cracks, white spots, or a broken element\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows on a heat call\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027553173875,"sku":"1171306","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047630618995,"sku":"1171306-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_38fed9d7-d408-4529-8ca3-53a831616a14.jpg?v=1782892230","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-rgs120leaa0agaa-with-wiring-kit-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}