{"product_id":"icp-hot-surface-igniter-for-rgs101lfca0aaa-oem-1171306-with-wiring-kit-ships-today","title":"ICP Hot Surface Igniter for RGS101LFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (HSI) assembly is the direct ignition component for the ICP \/ Heil \/ Tempstar RGS101LFCA0AAA gas furnace. The igniter (OEM part 1171306) glows red-hot when energized by the control board, lighting the burner gas on each heating call. This listing ships with the matching igniter wiring kit (OEM 1188370) so the connector pigtail and harness are replaced together, eliminating the brittle, heat-fatigued wiring that commonly fails alongside the igniter element itself. Hot surface igniters are a wear item — the silicon nitride\/carbide element degrades with every heat cycle and eventually cracks or fails open. Typical failure symptoms include no ignition, a furnace that clicks and tries to light but never fires, a visible crack in the igniter element, or a unit that locks out after several failed trials for ignition.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter) + 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRGS101LFCA0AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit replacement for the ICP\/Heil\/Tempstar\/Comfortmaker RGS101LFCA0AAA furnace and other RGS-series models that call out OEM igniter 1171306. Always confirm the original igniter part number stamped on your existing component or listed in your model's parts breakdown before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch\/breaker and shut off the gas supply. Verify zero voltage with a multimeter before touching any wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace front\/burner service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wire routing before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and lift the old igniter out of the burner assembly. Handle only by the ceramic base — never touch the fragile element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new igniter so the element sits correctly in the burner flame path, secure the mounting screw, and connect the new wiring kit harness\/connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace attempts to light but never ignites the burners.\u003c\/li\u003e\n\u003cli\u003eVisible crack, chip, or white\/gray spot on the igniter element.\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow when the heating cycle starts.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition trials.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027663241587,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047627014515,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_43c4c00c-e5c1-45fe-9ce9-1e55627c4f04.jpg?v=1782892116","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-rgs101lfca0aaa-oem-1171306-with-wiring-kit-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}